Abstract

Biocomposites with poly(ε-caprolactone) (PCL) as matrix and lignocellulosic hemp fiber with varying average aspect ratios (19, 26, 30 and 38) as reinforcement were prepared using twin extrusion process. The influence of fiber aspect ratio on the water absorption behavior and mechanical properties are investigated. The percentage of moisture uptake increased with the aspect ratio, following Fickian behavior. The hemp fiber/PCL bio- composites showed enhanced properties (tensile, flexural and low-velocity impact). The biocomposite with 26 aspect ratio showed the optimal properties, with flexural strength and modulus of 169% and 285% respectively, higher than those of neat PCL. However, a clear reduction on the mechanical properties was observed for water- immersed samples, with reduction in tensile and flexural moduli for the aspect ratio of 26 by 90% and 62%, respectively than those of dry samples. Summarily, the optimal sample provides an eco-friendly alternative to conventional, petroleum-based and non-renewable composites for various applications.

KeywordsComposites; Mechanics; Biomaterials; Sustainability; 0912 Materials Engineering; 0913 Mechanical Engineering; 0901 Aerospace Engineering; Materials
Year2018
JournalComposites Part A: Applied Science and Manufacturing
Journal citation113, pp. 350-358
PublisherElsevier
ISSN1359-835X
Digital Object Identifier (DOI)doi:10.1016/j.compositesa.2018.08.005
Publication dates
Print07 Aug 2018
Publication process dates
Deposited17 Aug 2018
Accepted06 Aug 2018
Accepted author manuscript
License
CC BY-NC-ND 4.0
Permalink -

https://openresearch.lsbu.ac.uk/item/869x1

Accepted author manuscript

  • 4
    total views
  • 0
    total downloads
  • 1
    views this month
  • 0
    downloads this month

Related outputs

Effect of SR-microCT radiation on the mechanical integrity of trabecular bone using in situ mechanical testing and digital volume correlation
Peña Fernández, M, Cipiccia, S, Dall'Ara, E, Bodey, AJ, Parwani, R, Pani, M, Blunn, GW, Barber, AH and Tozzi, G (2018). Effect of SR-microCT radiation on the mechanical integrity of trabecular bone using in situ mechanical testing and digital volume correlation. Journal of the Mechanical Behavior of Biomedical Materials. 88, pp. 109-119.
Preservation of bone tissue integrity with temperature control for in situ SR-MicroCT experiments
Fernández, MP, Dall'Ara, E, Kao, AP, Bodey, AJ, Karali, A, Blunn, GW, Barber, AH and Tozzi, G (2018). Preservation of bone tissue integrity with temperature control for in situ SR-MicroCT experiments. Materials. 11 (11).
Hydration dependent mechanical performance of denture adhesive hydrogels
Zhang, F, An, Y, Roohpour, N, Barber, AH and Gautrot, JE (2018). Hydration dependent mechanical performance of denture adhesive hydrogels. Dental Materials. 34 (10), pp. 1440-1448.
Type VI Collagen Regulates Dermal Matrix Assembly and Fibroblast Motility
Theocharidis, G, Drymoussi, Z, Kao, AP, Barber, AH, Lee, DA, Braun, KM and Connelly, JT (2016). Type VI Collagen Regulates Dermal Matrix Assembly and Fibroblast Motility. Journal of Investigative Dermatology. 136 (1), pp. 74-83.
Extreme Toughness Exhibited in Electrospun Polystyrene Fibers
Zhang, F and Barber, AH (2017). Extreme Toughness Exhibited in Electrospun Polystyrene Fibers. Macromolecular Materials and Engineering. 302 (9), pp. 1700084-1700084.
Structural orientation dependent sub-lamellar bone mechanics
Jimenez-Palomar, I, Shipov, A, Shahar, R and Barber, AH (2015). Structural orientation dependent sub-lamellar bone mechanics. Journal of the Mechanical Behavior of Biomedical Materials. 52, pp. 63-71.
Microscopy and supporting data for osteoblast integration within an electrospun fibrous network
Stachewicz, U, Qiao, T, Rawlinson, SCF, Veiga Almeida, F, Li, W-Q, Cattell, M and Barber, AH (2015). Microscopy and supporting data for osteoblast integration within an electrospun fibrous network. Data in Brief. 5, pp. 775-781.
3D imaging of cell interactions with electrospun PLGA nanofiber membranes for bone regeneration
Stachewicz, U, Qiao, T, Rawlinson, SCF, Almeida, FV, Li, W-Q, Cattell, M and Barber, AH (2015). 3D imaging of cell interactions with electrospun PLGA nanofiber membranes for bone regeneration. Acta Biomaterialia. 27, pp. 88-100.
The cytolinker plectin regulates nuclear mechanotransduction in keratinocytes
Almeida, FV, Walko, G, McMillan, JR, McGrath, JA, Wiche, G, Barber, AH and Connelly, JT (2015). The cytolinker plectin regulates nuclear mechanotransduction in keratinocytes. Journal of Cell Science. 128 (24), pp. 4475-4486.
3D nanomechanical evaluations of dermal structures in skin
Kao, AP, Connelly, JT and Barber, AH (2015). 3D nanomechanical evaluations of dermal structures in skin. Journal of the Mechanical Behavior of Biomedical Materials. 57, pp. 14-23.
Evaluation of bioprosthetic heart valve failure using a matrix-fibril shear stress transfer approach
Anssari-Benam, A, Barber, AH and Bucchi, A (2016). Evaluation of bioprosthetic heart valve failure using a matrix-fibril shear stress transfer approach. Journal of Materials Science: Materials in Medicine. 27 (2).
Failure mechanisms in denture adhesives
An, Y, Li, D, Roohpour, N, Gautrot, JE and Barber, AH (2016). Failure mechanisms in denture adhesives. Dental Materials. 32 (5), pp. 615-623.
Morphological and Mechanical Biomimetic Bone Structures
Parwani, R, Curto, M, Kao, AP, Rowley, PJ, Pani, M, Tozzi, G and Barber, AH (2016). Morphological and Mechanical Biomimetic Bone Structures. ACS Biomaterials Science & Engineering. 3 (11), pp. 2761-2767.
Micro-mechanical properties of the tendon-to-bone attachment
Deymier, AC, An, Y, Boyle, JJ, Schwartz, AG, Birman, V, Genin, GM, Thomopoulos, S and Barber, AH (2017). Micro-mechanical properties of the tendon-to-bone attachment. Acta Biomaterialia. 56, pp. 25-35.
Surface free energy analysis of electrospun fibers based on Rayleigh-Plateau/Weber instabilities
Stachewicz, U, Dijksman, JF, Soudani, C, Tunnicliffe, LB, Busfield, JJC and Barber, AH (2017). Surface free energy analysis of electrospun fibers based on Rayleigh-Plateau/Weber instabilities. European Polymer Journal. 91, pp. 368-375.
X-ray Imaging of Transplanar Liquid Transport Mechanisms in Single Layer Textiles
Zhang, G, Parwani, R, Stone, CA, Barber, AH and Botto, L (2017). X-ray Imaging of Transplanar Liquid Transport Mechanisms in Single Layer Textiles. Langmuir. 33 (43), pp. 12072-12079.
Stress concentrations in nanoscale defective graphene
Wang, C, Wang, J and Barber, AH (2017). Stress concentrations in nanoscale defective graphene. AIP Advances. 7 (11), pp. 115001-115001.
Nanointerfacial strength between non-collagenous protein and collagen fibrils in antler bone
Hang, F, Gupta, HS and Barber, AH (2013). Nanointerfacial strength between non-collagenous protein and collagen fibrils in antler bone. Journal of The Royal Society Interface. 11 (92), pp. 20130993-20130993.
Adhesion Anisotropy between Contacting Electrospun Fibers
Stachewicz, U, Hang, F and Barber, AH (2014). Adhesion Anisotropy between Contacting Electrospun Fibers. Langmuir. 30 (23), pp. 6819-6825.
Polarised infrared microspectroscopy of edge-oriented graphene oxide papers
Frogley, MD, Wang, C, Cinque, G and Barber, AH (2014). Polarised infrared microspectroscopy of edge-oriented graphene oxide papers. Vibrational Spectroscopy. 75, pp. 178-183.
Molecular force transfer mechanisms in graphene oxide paper evaluated using atomic force microscopy and in situ synchrotron micro FT-IR spectroscopy
Wang, C, Frogley, MD, Cinque, G, Liu, L-Q and Barber, AH (2014). Molecular force transfer mechanisms in graphene oxide paper evaluated using atomic force microscopy and in situ synchrotron micro FT-IR spectroscopy. Nanoscale. 6 (23), pp. 14404-14411.
Mechanical Behavior of Osteoporotic Bone at Sub-Lamellar Length Scales
Jimenez-Palomar, I, Shipov, A, Shahar, R and Barber, AH (2015). Mechanical Behavior of Osteoporotic Bone at Sub-Lamellar Length Scales. Frontiers in Materials. 2.
Extreme strength observed in limpet teeth
Barber, AH, Lu, D and Pugno, NM (2015). Extreme strength observed in limpet teeth. Journal of The Royal Society Interface. 12 (105), pp. 20141326-20141326.
Wetting Hierarchy in Oleophobic 3D Electrospun Nanofiber Networks
Stachewicz, U, Bailey, RJ, Zhang, H, Stone, CA, Willis, CR and Barber, AH (2015). Wetting Hierarchy in Oleophobic 3D Electrospun Nanofiber Networks. ACS applied materials & interfaces. 7 (30), pp. 16645-16652.
Approaches to 3D printing teeth from X-ray microtomography.
Cresswell-Boyes, AJ, Barber, AH, Mills, D, Tatla, A and Davis, GR (2018). Approaches to 3D printing teeth from X-ray microtomography. Journal of Microscopy.
Optimization of digital volume correlation computation in SR-microCT images of trabecular bone and bone-biomaterial systems.
Peña Fernández, M, Barber, AH, Blunn, GW and Tozzi, G (2018). Optimization of digital volume correlation computation in SR-microCT images of trabecular bone and bone-biomaterial systems. Journal of Microscopy.