Determination of Display Shelf Life of Sandwich Components

Conference paper


Hadawey, A, Tassou, S and Datta, D (2005). Determination of Display Shelf Life of Sandwich Components. IIR International Conference. Commercial Refrigeration. Vicenza Italy 30 - 31 Aug 2005
AuthorsHadawey, A, Tassou, S and Datta, D
TypeConference paper
Abstract

There is considerable demand for process design data on all aspects of food chilling, especially for unwrapped products. This is a result of strict product temperature legislation together with economic requirements to maximise throughput, minimise weight loss and operate refrigeration systems in the most efficient manner. Recent years have seen an increase in customer demand for fresh convenience food, which has caused a major increase in the volume of sales of unwrapped products. Surface drying has been identified as the main reason for commercial loss from unwrapped chilled food in display cabinets. Surface drying increases weight loss and leads to colour changes that are undesirable. This paper reports on work aimed at determining the mass transfer coefficients for some of the most common fillings used in unwrapped sandwiches under the environmental boundary conditions that exist in a display cabinet, and to evaluate their display shelf life and dehydration rate. It was observed that changes in relative humidity along with the air velocity have a substantial effect on drying rate. The measured drying rates were used to derive the average mass transfer coefficients, which are presented in the form of empirical equations that can be used in the selection of appropriate display cabinet environmental conditions to prolong shelf life and reduce wastage.

Year2005
Accepted author manuscript
License
Publication dates
Print30 Aug 2005
Publication process dates
Deposited29 Nov 2018
Accepted04 Jul 2005
Permalink -

https://openresearch.lsbu.ac.uk/item/87qy7

Download files


Accepted author manuscript
shelf life V4.doc
License: CC BY 4.0

  • 187
    total views
  • 99
    total downloads
  • 0
    views this month
  • 0
    downloads this month

Export as

Related outputs

Optical properties of PVC composite modified during light exposure to give high absorption enhancement
Abed, Rasheed N., Yousif, E., Abed, A.R.N., Rashad, A., Hadawey, A. and Jawad, A. (2021). Optical properties of PVC composite modified during light exposure to give high absorption enhancement. Journal of Non-Crystalline Solids. 570, p. 120946. https://doi.org/10.1016/j.jnoncrysol.2021.120946
Assessing the Horizontal Homogeneity of the Atmospheric Boundary Layer (HHABL) Profile Using Different CFD Software
Abohela, I, Aristodemou, E, Hadawey, A and Sundararajan, R (2020). Assessing the Horizontal Homogeneity of the Atmospheric Boundary Layer (HHABL) Profile Using Different CFD Software. Atmosphere. 11 (10), pp. 1138-1138. https://doi.org/10.3390/atmos11101138
Investigation of the performance characteristics of an ammonia-water absorption chiller in a tri-generation system arrangement
Hadawey, A, Tassou, S, Suamir, IN, Chaer, I and Marriott, D (2009). Investigation of the performance characteristics of an ammonia-water absorption chiller in a tri-generation system arrangement. 5th Heat Powered Cycles Conference. Berlin, Germany 07 Sep - 09 Nov 2009
Integration of CO2 refrigeration and tri-generation systems for supermarket Applications
Hadawey, A, Tassou, S, Suamir, IN and Marriott, D (2010). Integration of CO2 refrigeration and tri-generation systems for supermarket Applications. 1st IIR International Cold Chain Conference. UK, Cambridge 29 - 31 Mar 2010
Performance optimization of a secondary refrigerant display cabinet using tests and CFD modelling
Hadawey, A, Tassou, S, Jouhara, H and Suamir, IN (2010). Performance optimization of a secondary refrigerant display cabinet using tests and CFD modelling. 1st IIR International Cold Chain Conference. Cambridge, UK 29 - 31 Mar 2010
Energy Savings through Liquid Pressure Amplification in Refrigeration Systems
Hadawey, A, Tassou, S and Ge, YT (2010). Energy Savings through Liquid Pressure Amplification in Refrigeration Systems. Sustainable Refrigeration and Heat Pump Technology Conference. Stockholm, Sweden 14 - 18 Jun 2010
Liquid Pressure Amplification in Refrigeration Systems – Potential for Reducing Energy Consumption in Retrofit Applications
Hadawey, A, Tassou, S and Ge, YT (2010). Liquid Pressure Amplification in Refrigeration Systems – Potential for Reducing Energy Consumption in Retrofit Applications. SEEP 2010 Conference Proceedings. Bari, Italy 29 Jun - 02 Jul 2010
Experimental Study of a Light Commercial Refrigeration System Operating Under Frosting Conditions
Hadawey, A, Tassou, S and DA Silva, D (2011). Experimental Study of a Light Commercial Refrigeration System Operating Under Frosting Conditions. The 23rd IIR International Congress of Refrigeration. Prague, the Czech Republic 21 - 26 Aug 2011
Air Curtain Design Optimization of Refrigerated Vertical Display Cabinet using CFD
Hadawey, A, Jaber, T, Abdul Ghaffar, W and Hasan, A (2012). Air Curtain Design Optimization of Refrigerated Vertical Display Cabinet using CFD. International Journal of Engineering, Science and Technology. Volume (ISSN:).
Theoretical and experimental study of bubbly gas-water two phase flows through a Universal Venturi Tube (UVT)
Hadawey, A, Hasan, A, Al-Wahaibi, Y, Abdul-Karem, W and Al-Raheem, KF (2012). Theoretical and experimental study of bubbly gas-water two phase flows through a Universal Venturi Tube (UVT). International Journal of Information Science and Engineering. 2 (1), pp. 43-58.
Numerical Investigation into the Product’s Weight loss and Display Shelf life inside the Serve-over Cabinet
Hadawey, A (2018). Numerical Investigation into the Product’s Weight loss and Display Shelf life inside the Serve-over Cabinet. 2nd International Conference on Sustainable Energy and Resource Use in Food Chains, ICSEF 2018. Cyprus, Pahpos 17 - 19 Oct 2018
Unwrapped food product display shelf life assessment
Hadawey, A, Tassou, SA, Chaer, I and Sundararajan, R (2017). Unwrapped food product display shelf life assessment. Energy Procedia. 123, pp. 62-69. https://doi.org/10.1016/j.egypro.2017.07.233